Altelix 24x24x16 Steel Weatherproof NEMA Enclosure with Dual Door Mounted Cooling Fans, Dual 120 VAC Duplex Outlets and Power Cord
The Altelix NS242416LVFA1C Steel Fan Cooled Weatherproof NEMA Enclosure with 120VAC Power and Equipment Plate is ideal for protecting equipment from harsh environments and tampering. Equipment designed for indoor use can now be located outside.
Construction and Features
This rugged enclosure features continuous seam welded 18 Gauge (1.2mm thick) steel construction. The enclosure door is fully gasketed making this enclosure suitable for use indoors or outdoors. The door features reinforced hinges and dual quarter-turn latches to secure the enclosure. Internal grounding studs are provided on both the door and enclosure.
Both the enclosure and door are finished in a rugged epoxy polyester textured light gray powder coat finish.
Bonus Aluminum Bottle Opener Key
This enclosure now includes our HN-0008 Aluminum Bottle Opener Key. A $9.99 value, this heavy duty aluminum door locking key easily attaches to most key chains. And it makes a great bottle opener too!
Removable Power Module
The NS242416LVFA1C features a removable power module that attaches to the bottom of the enclosure. Constructed of rugged aluminum, this can be easily removed for servicing and is fully gasketed to ensure a proper seal. This power module features two pre-wired duplex 120VAC power outlets (4 outlets total) and a pre-wired 5 foot power cord, so no additional wiring is required.
Dual Door Mounted Cooling Fans
This enclosure features two (2) thermostat controlled 120mm cooling fans. These door mounted low noise, high airflow fans provide better air flow through the enclosure than bottom mounted fans and help maintain lower internal temperatures. The fans turns on when the internal temperature reaches 100°F (38°C) and turns off when it drops to 79°F (26°C). Both fans are wired internally so it does not require the use of the AC outlets leaving them available for internal equipment use. Powder coated aluminum rain shrouds on the front door keep rainwater from entering the enclosure.
Galvanized Steel Equipment Plate
This configuration consists of the steel NEMA enclosure with hinged door and a 18 Gauge (1.2mm thick) zinc coated galvanized steel plate for mounting and securing equipment. The enclosure and plate can be drilled and modified by the installer to suit unique site requirements.
Cable Glands
The enclosure features two unique PG-16 cable glands with a closed inner seal. They are installed in the open ports to maintain the NEMA rating of the enclosure when not in use. When required for use, simply punch a hole through the inner membrane, run your cables and tighten for a water-tight seal.
Mounting
Mounting holes are provided inside the enclosure for mounting to a wall or other structure. For pole mounting Altelix has available the optional NMHS-600-16 pole mount kit. This heavy-duty kit features (2) 14 gauge steel mounting brackets and (2) heavy-duty 19 gauge 304 stainless steel adjustable bands which can be used to mount to poles from 4.5" (114.3mm) to 16" (406.4mm) in diameter.
Optional Lockable Latches
For additional protection of internal equipment installed, two lockable latches are available. The HN-0005 is a keyed lock set which includes two keys. The HN-0006 allows the enclosure to be securely locked via use of a padlock (not included). Both the HN-0005 and HN-0006 are direct replacements for the standard quarter-turn latches that come pre-installed in the enclosures.
Customization
This enclosure is one of many standard models available. Our lineup includes enclosures specifically tailored for WiFi equipment, DIN Mount Industrial Controls, POTS Telephones, IP Phones, Device Charging Stations, Security & Safety Equipment, Building & Home Automation and More.
We offer numerous standard models and options including equipment mounting plates, DIN rails, AC or DC power, air vents, cooling fans and heaters and more. We also offer full customization, engineering and on-site CNC machining of enclosures and associated equipment, all with quick turnaround time. Please contact us with your unique requirements.
Features
Features
| Applications
|
Specifications
Material | Continuous Seam Welded 18 Gauge (1.2mm) Steel |
Color | Light Gray (RAL 7035) |
Voltage | 120VAC |
Max Load | 10A @ 120VAC |
Cooling Fans Turn-On Temperature | 100°F (38°C) ±6°F |
Cooling Fans Turn-Off Temperature | 79°F (26°C) ±9°F |
Exterior Dimensions (Height x Width x Depth) | 23.6 x 23.6 x 17.2 Inches (600 x 600 x 437 mm) |
Interior Dimensions* (Height x Width x Depth) | 18.0 x 20.0 x 12.3 Inches (457 x 508 x 312 mm) |
Equipment Plate Material | 18 Gauge (1.2mm) Zinc Coated Galvanized Steel |
Equipment Plate Dimensions | 22.2 x 21.6 In. (565 x 550 mm) |
Weight | 50.4 lbs. (22.8 kg) |
Power Cord Length | 5 Feet (1.5m) |
Ratings | NEMA Type 3R, 3RX / IP24 |
*Notes: 1) Interior dimensions represent maximum space available for equipment. |